Why choose the Meditherm med2000™

Meditherm med2000 maximizes the potential of thermography for the best possible diagnosis and treatment by delivering a higher degree of sensitivity and specificity than other systems.

Only thermography system specifically designed and calibrated for optimal operation in the narrow temperature range of metabolic heat.

Meditherm has the largest network of doctors and technicians worldwide and is the industry leader with the oldest established infrastructure covering manufacture, marketing, training, and after sales support.
Efficient internal reference temperature of the Med2000 Iris and auto correction with unique agile processing technology eliminates the problems of thermal drift suffered by other cameras.
Most accurate readings because each pixel is an individually referenced measurement which can be compared to any other pixel within an image and also image to image, and comparisons over time.
Instantly and automatically saves images to laptop or PC without any intermediate steps; image manipulation and statistical data immediately available.
User friendly software ……… Really!
Access to EMI interpretation service with quickest turnaround of reports at the lowest fees.
Can focus on regions of interest from 2 inches to infinity, while detecting 100% of the body’s emitted infrared Radiation.
Permits less critical protocols in your clinic without sacrificing accuracy and reliability.
Can be used in all clinics and offices with full body exams taking less than 15 minutes.
Maintenance-free, no consumables, simpler and more durable.
The Med2000 systems will generate good bottom line profits with minimal investment and time.
The most competitive price worldwide

The meditherm med2000™ has a 20 year history of successful performance and the reliability of the Meditherm med2000™ has been proven in many countries throughout the world.

The meditherm med2000™ is maintenance free and has no consumables. (So you can use your system confidently over the years, we offer an economic re-calibration service recommended every 2 years!)


Most FPA systems are designed primarily for industrial use and detect temperatures from 0°C to well over 150°C so the sensitivity of the detector array is spread over a much wider potential temperature range, (Temperature difference from hottest to coldest or the window of temperatures detected) Although this range can be adjusted it is the automatic averaging of the hottest and coldest measurements recorded throughout the whole image which are constantly changing that cause problems and further confuse the results.

Meditherm med2000™ is designed and calibrated for optimal operation in the narrow temperature range pertinent to, and specific for detecting and recording metabolic heat, (10°C - 40°C).

The meditherm med2000™ can apply specific and stable temperature ranges necessary for diagnosis during or after scanning.


The actual picture of the patient seen with FPA is a 'colourmap' divided throughout the total range of temperature seen by the array. The colours that are used in the thermogram are divided though-out the whole range of temperatures detected, i.e. the background around the patient will be using up some of the allocated colours (and sensitivity), hence a loss of specificity. Features like 'edge enhancement' are also used at the expense of specificity.

Thermal mapping is more accurate with the meditherm scanning technology because each pixel is an individual temperature measurement (sensitive to 0.01°C ) that can be compared to any other pixel, the meditherm med2000™ can and does apply its total colour range, (and range of temperature) to the patient alone which gives us far more sensitivity and specificity!


Industrial FPA technology is not as suitable for medical applications because of it's averaging of groups of pixels in order to handle the 'bad' pixels, thermograms produced with un-cooled FPA also suffer from 'thermal drift' and poor range control.

The accuracy and reliability (repeatability) that the Meditherm med2000™ achieves is in part due to the efficiency of the thermoelectric cooling of the detector, (our system does not suffer from the problems of 'thermal drift' as do some un-cooled cameras).


To achieve usable results with an industrial FPA very strict operating protocols have to be followed.

This isn't always easy in practice, but the increased sensitivity and specificity provided by the meditherm med2000™ allows you to still record accurate images with far less critical protocols.


The optics used with industrial FPA systems actually reduce their detection accuracy as these lenses can stop from 10% to 20% of infrared radiation being detected.

Meditherm med2000™ does not rely on lenses but can focus a region of interest from 2" to infinity while still detecting 100% of infrared radiation.


Using a small handheld industrial FPA camera each image is viewed in a proprietary format, which requires processing with industrial software.

Meditherm med2000™ instantly saves each image to the laptop or PC with no intermediary steps. Image manipulation and statistical data is instantly available for each and every image whether saved or not.

Thermograms produced by the Meditherm med2000™ are stored as TIFF images, which can be accessed and manipulated with a wide range of off-the-shelf application software.

The key to the success of the Meditherm med2000™ is simplicity and control!

©Copyright 1997 - 2016 by Meditherm,Inc. All rights reserved.
Last modified: January 19, 2016
Meditherm is a registered trademark of Meditherm,Inc.
All registered trade marks and logos are proprietary to their respective owners.